Water level indicator vs water level controller, Waterline Controls
Written by Waterline Controls

Water Level Indicator vs Water Level Controller

A water level indicator is a device that reports the height of water in a tank. A water level controller is a device that switches outputs at defined levels to command pumps, valves or alarms. Specify both when operators need a level reading and the system also needs automatic control.

A Level Indicator Shows Where the Water Is

Indication tells the operator approximately where the water surface sits over a measurement range.

This is useful for large storage tanks, well tanks, process vessels and systems where operators need more than a few alarm points.

The WLI water level indicator from Waterline Controls uses a capacitive probe and a 0 to 20 mA current output for remote indication. Its output moves in 5 percent steps over the length of the probe, with a stated accuracy of plus or minus 10 percent. Waterline Controls describes the WLI as a level indicator only, not a level controller.

A Level Controller Acts at Defined Levels

A controller does not need to report every inch of water depth to do its job.

Instead, separate sensor points represent functions such as fill start, fill stop, high alarm and low alarm. The WLC-5000 water level controller, for example, uses separate probes for fill start, fill stop, high alarm and low alarm.

When water reaches one of the defined levels, the controller changes a relay or remote contact according to the sequence.

Continuous Measurement Has Different Uses

A level signal is useful when operators want to display percent of measured depth, trend level changes or estimate stored volume using the tank’s level-to-volume relationship.

A 4 to 20 mA analog signal is a standard output for continuous level transmitters. The WLI’s output is 0 to 20 mA, it requires 24 VDC and it can drive a load of up to 1100 ohms, so confirm that the receiving analog input accepts that range and load.

If the design uses an analog signal to operate pumps or alarms, specify where the setpoint logic runs. A controller with discrete functions provides those actions directly.

Can a Water Level Indicator Control a Pump?

Not unless it is designed for it. Waterline Controls states that its WLI series is designed as a level indicator only and should not be used as a level controller.

If automatic filling or pump control is required, specify a device designed for that function. Do not assume every transmitter or display includes the necessary relay logic.

Some Projects Benefit From Both

A well water storage tank is a good example.

The facility may want remote indication of tank water level while also needing independent automatic control of the supply pump and high or low alarms. Waterline Controls notes that the WLI can be used together with its WLC series level controls.

The two systems should use clearly defined signals so operators understand which device is controlling equipment.

Indicator vs Controller at a Glance

Water level indicator (WLI) Water level controller (WLC-5000)
What it reports Level across the probe range, in 5 percent steps Whether water is at each defined level
What it does at a level Nothing; it is an indicator only Starts and stops the fill, activates high and low alarms
Signal to the BMS 0 to 20 mA analog Dry contacts for fill, high alarm, low alarm and power loss

Choose the Right BMS Signal

Analog signals and dry contact points are handled differently by building automation. An analog signal represents a changing value. A dry contact can represent a condition such as high alarm or a fill command.

The BMS point schedule should identify the signal type as well as the point name. That prevents controls contractors from expecting an analog level value from a controller designed only to provide discrete outputs. For the discrete side, see what BMS points a water level controller should report.

Specify the Function Before the Device

Start by deciding what the facility actually needs to know and what it needs the system to do.

If the requirement is only to display tank level, an indicator may be enough. If pumps, valves or alarms must operate automatically, specify control. If both are required, design both functions intentionally.

Water Level Indicators and Controllers for Commercial Tanks

Waterline Controls manufactures frequency-based electronic water level controllers and the WLI water level indicator for remote tank level indication. The WLC series provides automatic control and alarm functions, while the WLI reports level across the probe range in 5 percent steps. Call 480-905-1892 to discuss the tank, the signals you need and the BMS interface before selecting equipment.

References

WLI water level indicator

WLC-5000 water level controller with high and low alarms