V2.0 Nexus

Two Sensor Technologies.
One Control Panel.

Mission-Critical Redundancy

Specify the Nexus V2.0 and solve your requirement in one submittal. Contact-based level control and 4-20mA indication with automatic sensor failover.

One specification. One coordination drawing. One BMS connection.

ETL Listed UL 508 | Division 22/23 Specification Available

Nexus V2.0 Custom Control Panel — two sensor technologies, one enclosure

Trusted by Fortune 500 Data Centers for Mission-Critical Applications

Dual-sensor redundancy where failure is not an option

Specification Resources

Download instantly or have everything emailed to you.

Datasheet
PDF, 2 pages
Download
CSI Div 22
Word/PDF
Download
CSI Div 23
Word/PDF
Download
BIM/Revit
RFA
Download
Wiring
DWG/PDF
Download
Dimensions
CAD/PDF
Download

Email All Files

Files will be sent to your inbox shortly.

One quick question — which spec platform does your firm use?

Where Nexus V2.0 Excels

Dual-sensor redundancy solutions built for code-compliant applications

Wastewater Pump Controls

Wastewater codes require two independent sensor technologies. Nexus is the only panel that integrates both in a single enclosure — eliminating the need to spec and coordinate two separate systems.

  • One panel replaces two — dual-tech redundancy built in
  • Frequency-based sensing won't foul in raw sewage
  • Duplex pump alternation with HMI status display
  • Single coordination drawing, single BMS point

Lift Station Controls

Lift station codes demand dual-sensor redundancy with independent technologies. Nexus delivers both in one panel — no mechanical floats to fail in raw sewage.

  • Code-compliant dual redundancy in single enclosure
  • No moving parts — frequency sensing survives raw sewage
  • Lead/lag pump alternation extends motor life
  • HMI shows real-time levels and alarm status

Fire Protection Tank Controls

NFPA 22/20 requires dual-sensor redundancy for fire suppression water storage. Nexus meets the code in one ETL-listed panel — simplifying your specification.

  • NFPA 22/20 dual-redundancy requirement — built in
  • ETL Listed (UL 508A) for fire protection applications
  • Primary + secondary sensor in single NEMA enclosure
  • BMS integration: BACnet, Modbus, dry contacts

HVAC Cooling Tower Controls

Chemically treated cooling tower water destroys conductivity probes. Nexus uses frequency-based sensing that won't foul — delivering 15+ years of maintenance-free operation.

  • Frequency-based sensing — no fouling in treated water
  • 15+ year sensor lifespan vs. 2-3 years for conductivity
  • Optional dual-sensor for mission-critical data centers
  • Maintains levels within 1/8" for optimal efficiency

Dual Functions. One Panel.

Every application needs a controller to act on level changes and an indicator to report tank status. The Nexus V2.0 collapses both into one enclosure — one coordination drawing, one BMS connection. Built-in failover means the indicator loop takes over automatically if the controller faults.

Level Controller

Multi-setpoint level control — pump sequencing, lead-lag alternation, high/low alarms. Operates autonomously, independent of BMS.

Recommended: frequency-based sensor.*

Nexus V2.0 Custom Control Panel — integrated level controller and level indicator
Level Indicator

Continuous, real-time tank level on the built-in HMI touchscreen and fed to your BMS via BACnet or Modbus. Also serves as backup control source on primary fault.

Without Nexus: 2 panels, 2 conduit runs, 2 power feeds  —  With Nexus: 1 panel, 1 conduit run, 1 power feed
Quick Turnarounds
Fast shipping on in-stock items
USA Made
Assembled in Scottsdale, Arizona
5-Year Warranty
Industry-leading coverage
ETL Listed
UL 508 certified

*Why Frequency-Based Sensing?

The Nexus V2.0's level controller uses WLC's proprietary frequency-based technology — not conductivity. Here's what that means for your specification.

Factor Waterline Controls Conductivity Systems (Warrick, Gems)
Core Technology Frequency-based (software-driven) Electrical conductivity between probes
How It Works Probes don't conduct electricity - no deterioration Passes 8-110VAC between probes through water
In Dirty/Hard Water No fouling or buildup Probes foul, pit, and deteriorate
Sensor Lifespan 15+ years 2-3 years typical
Recommended Maintenance Zero Periodic cleaning and replacement
Dual-Sensor Panel Nexus V2.0 - Built-in Requires two separate systems
Uptime 99% (documented) Varies by water quality
Warranty 5 years 1-2 years typical
Certification ETL Listed (UL 508) UL Recognized (component only)

Code Compliance & Certifications

NFPA 22 & NFPA 20
Dual-sensor redundancy requirement met
ETL Listed UL 508A
Industrial control panel standard
BMS/BAS Integration
BACnet, Modbus, dry contact outputs
NEMA 4X Enclosure
Available for washdown environments
Made in USA
Assembled in Scottsdale, Arizona

Inside the Enclosure: Modular by Design

Every Nexus V2.0 is built to your specification. Choose your sensor inputs, pump control logic, voltage, and connectivity — we engineer the panel to your application requirements.

Dual Sensor Inputs

Contact-Based + 4-20mA Analog

  • WLC Frequency Sensor* (recommended)
  • Float Switch or Conductivity Probe
  • Pressure Transducer, Ultrasonic, or Radar

Both inputs active simultaneously — controller acts on level thresholds, indicator reports continuous range. Complementary sensing with automatic failover.

HMI Touchscreen

Real-Time Visibility for Both Loops

  • Pump Status, Active Alarms, Operating Levels
  • On-Site Diagnostics and Test Functions
  • Single Display for Controller + Indicator Data

See both loops on one screen. Monitor, diagnose, and verify operation without opening the enclosure or connecting to BMS.

Duplex Pump Control

30A Relay Output → Dual Pump Operation

  • Alternating, Simultaneous, or Lead-Lag Modes
  • Balanced Run Times with Configurable Delays
  • High/Low Alarms, Sensor Fault Detection

Operates autonomously — no BMS required. Configured to your voltage and pump FLA requirements.

Connectivity Options

Dry Contacts → BACnet/Modbus → LoRaWAN

  • Standard Dry Contact Outputs to BAS
  • BACnet or Modbus via Single BMS Address
  • Optional LoRaWAN® Wireless Monitoring

One integration point for both loops. Add LoRaWAN for remote visibility and IoT network alerts — no hardwired infrastructure required.

Built to Your Specification

8+ sensor types. 3 pump control modes. 4 connectivity options. Configured to your voltage and pump FLA, in a NEMA 4X enclosure with custom ratings available. Pre-wired, pre-programmed, and backed by a 5-year warranty. Our Arizona-based engineering team works with you to specify the right combination — typically responds within 1 business day.

Request Engineering Support

Our Arizona-based engineering team typically responds within 1 business day.

Typical response: < 1 business day • Direct from our Arizona engineering team

Request Received

Our engineering team will contact you within 1 business day.

One quick question — which spec platform does your firm use?

We're investing in spec platform integrations to make your job easier.

Thank you for your feedback!