  • WLC9000 – Dual Pump Down | High Level Set Point

    Features:

    • Time delay between sensing and the Secondary High Water Level pump or gate valve, before initializing the relay, to activate the Secondary High Water Level Pump Down System
    • Time delay between sensing and the High Water Level Alarm before initializing the relay to activate the High Water Level Alarm
    • Switch to activate the test process to automatically cycle through the Pumping process, Secondary High Water Level Pump Down and the High Water Level Alarm
  • WLC9100 – Lead-Lag Dual Pump Down Alternating Pumps w/High Level Set Point

    Features

    • There is a time delay between sensing and Pump Down before initializing a pump or gate valve
    • The system has a time delay between sensing and the Secondary High Water Level pump or gate valve before initializing the relay to activate the Secondary High Water Level Pump Down System
    • The system has a time delay between sensing and the High Water Level Alarm before initializing the relay to activate the High Water Level Alarm
    • There is a switch to activate the test process and it will automatically cycle through the:
      • Pumping process
      • Secondary High Water Level Pump Down
      • High Water Level Alarm
  • WLC8000 – Pump Down with High Level Set-point and High Water Level Alarm

    Features:

    • Fill With High alarm
    • For sump systems in commercial buildings
    • Operates any size pump
  • WLC-7000 Pump Down System

    Features

    The system is comprised of a sensor and sensor housing with wire attached and installed at water level operating range, control panel mounted at a convenient location and a relay to operate a pump or gate valve.

  • WLC6000 – Fill | High / Low Alarms | Low-Low Heater Cut Off

    Features

    • 4-Contact point system
    • 10-wire Dry contacts to BMS for measuring:
      • Fill “ON” time
      • High Water Alarm and Fault conditions
  • WLC5000 – Fill W/High and Low Alarm

    Features

    • Fill w/ High Alarm
    • 3-Contact point system
    • 8-wire Dry contacts to BMS for measuring:
      • Fill “ON” time
      • Low Water Alarm
      • High Water Alarm
      • Fault conditions
  • WLC4500 – Fill with Low Alarm

    Features:

    • Fill w/ Low Alarm
    • 2-Contact point system
    • 6-wire Dry contacts to BMS for measuring:
      • Fill "ON" time
      • Low Water Alarm
      • Fault conditions
  • WLC4000 – Fill W/High Alarm

    Features:

    • Fill w/ High Alarm
    • 2-contact point system
    • 6-wire Dry contacts to BAS for measuring:
      • Fill “ON” time
      • High Water Alarm
      • Fault conditions.
  • WLC3000 – Fill Only

    Features:

    • 4-wire Dry contacts to BMS for measuring:
      • Fill "ON" time
      • fault conditions
  • What You Should Know About Sensor Types and Why It’s Important

  • Water Level Indicator Capacitive Sensor Probe

    • Flow Diagram
  • WLC6100T – Fill with High and Low Alarms and Basin Heater Controls

    Features

    • 4-Contact point system with one temperature sensor
    • 10-wire Dry contacts to BAS for measuring:
      • Fill “ON” time
      • High Water Alarm
      • Low Water Alarm
      • Heater "ON"
      • Fault conditions
  • Audio Alarm-Internal

    -
    • -

    110db Audible Alarm – Mounted and wired internally

    WaterLine Controls™ Audible Alarm

    This alarm can be heard in a mechanical room or outdoors. It is very loud with a very disguised sound.

    We use the relays that are already in the enclosure. It can be wired to any relay and we do that for you at the factory. We have wired it into both the high alarm and the low alarm at the same time so only one alarm is needed.

    The Control Panel is still considered NEMA4X since this alarm is rated the same

  • WLC-WS3000

    -
    • -

    FILL ONLY – INTERNAL DIAGNOSTIC TEST SYSTEM

    WaterLine Controls™ WLC-WS3000 Specification – Set Points for: Fill ONLY for up to 5HP Pump

    The Model WLC-WS3000-220-50 (This is a sensor wire length of 50 Feet) Waterline Controls Unit manufactured by System Dynamics, Inc (888-905-1892) and supplied by System Dynamics, Inc (888-905-1892) shall be supplied as a unit, including sensor with wire, controller and mounting assembly parts. A properly sized pump shall be supplied by others. The level control system shall consist of solid-state parts with non-corrosive components and is suitable for use outdoors in an industrial or residential application or indoors in a mechanical room environment. The level control system will provide automation monitoring outputs, fine control, ease of operation, ease of service and accessibility. The Control Panel shall come with a 5 Year Limited Warranty, which can be copied from: https://waterlinecontrols.com/pdfs/Lifetime_Limited_Warranty%5B1%5D.pdf and submitted.

    The well water water level control system shall be automatically controlled within a range identified as “the operating range” (this range will be changed by the custom length probes being cut in the field). This condition has three outputs each which are: 1. Close a set of dry contacts for the BAS, 2 - operate a relay rated at 40AMPS for 250VAC (5HP Motor or less) and 3 - turn on an LED to indicate this sensor has tripped.

    The water level control system shall be comprised of a sensor mounted inside a 3” sensor housing with wire attached that is suitable to be placed in a wet environment and installed at the water level. A separate control panel, which is to be mounted outside of the wet environment within a distance of less than 50 feet (250 feet is the maximum length of a sensor wire that can be supplied).

    The 3” sensor housing shall be installed according to the drawings. The sensor head and its assembly will consist of 3 inch PVC plug, three pre-cut ¼” round stainless steel probes with thread ends. The adjustment of the sensing system shall be accomplished by adding intention rods as necessary to fit inside the operating range.

    The Control Panel must be certified by an independent third party testing facility (e.g., UL or ETL) to meet Standard UL508 or equivalent for the country in which it is installed. The level control panel shall draw no more than 0.25AMPS at 110VAC or 0.125 Amps at 220VAC. All power relays shall be rated at 40Amps at 250VAC for the normally open relay contacts. All three level outputs shall have a corresponding set of normally open dry contacts rated at 0.5Amps at 60Volts to be connected to an automation system if desired.

    The Control Panel shall have visual displays indicating power to the level control panel, when the control panel is actively filling. The control panel shall have a self-test button which cycles through and turns on each function in sequence for at least 10 seconds to allow for trouble-shooting as needed. This trouble-shooting feature shall operate without removing wires or disconnecting the sensing probes. This feature will be automatic and activated by pushing a button. There shall be an indicator (a Yellow LED) to indicate that this feature is operating. The Control Panel shall have an indicator which tells the operator when there is debris fouling the probes. The Control Panel shall have an automatic reset system if the well pump stays on for longer than six hours without turning off. It shall have a corresponding set of dry contacts that alerts (Closing a dry contact) the automation system.

    The Control Panel shall be of modular construction such that relays that control the above features can be removed and replaced without replacing the PCB or transformer.

  • WLC-WS4500

    Features

    • Fill "ON" time
    • Low Water Alarm
    • Fault conditions
    • Operates any 5HP pump or less
  • WLC-WST4500

    Features

    • Fill "ON" time
    • Low Water Alarm
    • Fault conditions
    • Internal 24VAC transformer
  • Vanstone Flange

    Features

    • Direct replacements for Evapco
    • Available in any length
  • External Static Pipe

    Features

    • 3" Sensor head which fits into any 3" Slip Style fitting
    • Approximately 20” long
  • Dual Sensor Probe Assembly

    Features

    • The Dual can be used on any model except the WLC-6100T
    • The probes can be mounted into two different environments
    • Single switch located on the WaterLine Controls panel
  • Internal Static Pipe Sensor

    Features

    • Sensor head which fits into any 3" Slip Style fitting
    • Standard sensor that comes with every kit


1 2 3