Waterline Control Models Matrix

COOLING TOWER WATER LEVELS & CONTROLS

PRODUCT FUNCTION TRUTH TABLE  The Blank spaces below mean “No Connection or Function” *All controls have built-in self testing systems.
MODEL BMS DRY CONTACTS POWER RELAY
FAULT POWER LOSS HEATER CUT OFF LOW ALARM HIGH ALARM FILL BAS WIRES HEATHER CUT OFF LOW ALARM HIGH ALARM FILL SELF TEST HEATER CONTROL
WLC3000 X X X 4 X X Fill Height Only
WLC4000 X X X X 6 X X X Fill Height with High Level Alarm
WLC4500 X X X X 6 X X X Fill Height with Low Level Alarm
WLC5000 X X X X X 8 X X X X Fill Height with High and Low Alarm
WLC6000 X X X X X X 10 X X X X X Fill Height with High and Low Level Alarm and Low Level Cut-off
WLC6000T X X X X X X 10 X X X X X X Fill Height with Temperature controls for Basin Heater

WELL WATER HOLDING TANKS

PRODUCT FUNCTION TRUTH TABLE  The Blank spaces below mean “No Connection or Function”
MODEL BMS DRY CONTACTS POWER RELAY
FAULT POWER LOSS LOW ALARM FILL BAS WIRES LOW ALARM FILL SELF TEST 5HP 24VAC
WLC3000 X X X 4 X X Fill Height Only
WLC WS-3000 X X X 4 X X X
WLC WST-3000 X X X 4 X X X

FIRE PROTECTION SYSTEMS

ALARM MODELS DESCRIPTION PROBE CONFIG. AUDIBLE ALARMS OPTIONS BMS DRY CONTACTS POWER RELAY
TOTAL NUMBER FAULT POWER LOSS LOW ALARM HIGH ALARM LOW-LOW ALARM SERVICE LEVEL BAS WIRE LOW ALARM HIGH ALARM LOW LOW ALARM SERICE LEVEL SELF TEST
FPT-30A Low Water Alarm Only 3 PROBE 1 TEMP 3 X X X 6 OPTIONAL 2
FPT-45A Low Water and Service Level Alarms Only 4 PROBE 2 TEMP 5 X X X X 6 X INCLUDED 3
FPT-50A Service Level Alarm With Low and High Alarm 5 PROBE 3 TEMP 7 X X X X X 8 X X INCLUDED 3
FPT-60A Service Level Alarm with Low and High Alarm & Low Low Alarm 6 PROBE 3 TEMP 9 X X X X X X 10 X X X OPTIONAL 2
CONTROLS MODELS OPTIONAL 2
FTP-30 Fill only 3 PROBE TEMP 3 X X X 6 OPTIONAL 2
FPT-45 Service Level Fill Control with Low Alarm 4 PROBE 1 TEMP 5 X X X X 6 X OPTIONAL 2
FTP-50 Service Level Fill Control with Low Alarm and High Alarm 5 PROBE 2 TEMP 7 X X X X X 8 X X INCLUDED 2
FTP-60 Service Level Fill Control with Low Alarm and High Alarm 6 PROBE 3 TEMP 9 X X X X X X 10 X X X OPTIONAL 2

SUMP CONTROLS & ALARMS

MODEL BMS DRY CONTACTS POWER RELAY
FAULT POWER LOSS ALTERNATES BETWEEN PUMP 1 PUMP2 HIGH ALARM PUMP/ ALARM 1 PUMP/ ALARM 2 BAS WIRES ALTERNATES BETWEEN PUMP 1 PUMP2 HIGH ALARM PUMP/ ALARM 1 PUMP/ ALARM 2 SELF TEST
WLC7000 X X X 4 X X Only 110VAC (High Alarm)
WLC8000 X X X X 6 X X X Drain with High Level Alarm 110VAC
WLC9000 X X X X 6 X X X X
WLC9100 X X X X X X 8 X X X X X

BOILER CONTROLS & ALARMS

MODEL BMS DRY CONTACTS POWER RELAY TIME DELAYS Each requires 2 wires MANUAL/REMOTES SWITCH RESET PROBES
FAULT POWER LOSS BURNER CUT OFF FILL BAS WIRES BURNER CUT OFF FILL LWC LOCK OUT LW OFF HWC ON AUTO TEST TEST CYCLE LOCK OUT LWCD REST TEST FILL
BLC3201 X X X 4 X OPTIONAL 2
BLC3302 X X X X 6 X X INCLUDED 3
BLC3303 X X X X 8 X X 90 SEC X INCLUDED 3
BLC3204 X X X 4 X 15 30 OPTIONAL 2
BLC3205 X X X 15 30 10 MIN 60 SEC OPTIONAL 2
BLC3206 X X X 4 X 15 30 20 MIN 60 SEC OPTIONAL 2
BLC3207 X X X 4 X 15 30 15 MIN 60 SEC OPTIONAL 2
BLC3208 X X X 4 X INCLUDED 2
BLC3209 X X X 6 X 30 SEC X X X OPTIONAL 2
BLC3210 X X X 6 X 30 SEC X X OPTIONAL 2
BLC3211 X X X 4 X X OPTIONAL 2
BLC3212 X X X 6 X 30 SEC X X OPTIONAL 2
BLC3213 X X X 4 X 15 30 20 MIN 90 sec OPTIONAL 2
BLC3215 X X X 4 X INCLUDED 1
BLC3214 X X DRAIN DRY CONTACTS AND DRAIN POWER RELAY 2

COMMERCIAL SWIMMING POOLS & FOUNTAINS

PRODUCT FUNCTION TRUTH TABLE  The Blank spaces below mean “No Connection or Function” *All controls have built-in self testing systems.
MODEL BMS DRY CONTACTS POWER RELAY
FAULT POWER LOSS HEATER CUT OFF LOW ALARM HIGH ALARM FILL BAS WIRES HEATHER CUT OFF LOW ALARM HIGH ALARM FILL SELF TEST HEATER CONTROL
SWS3000 X X X 4 X X Fill Height Only
SWS4000 X X X X 6 X X X Fill Height with High Level Alarm
SWS4500 X X X X 6 X X X Fill Height with Low Level Alarm
SWS5000 X X X X X 8 X X X X Fill Height with High and Low Alarm
SWS6000 X X X X X X X X X X X X Fill Height with High and Low Level Alarm and Low Level Cut-off